Selection Guides
How to Choose a Telecentric Lens for Measurement
Published
Four steps from field of view, sensor size and magnification to working distance to lock in the right telecentric lens.

Step 1: Define the field of view
Measure the largest dimension of your part and add 10%–20% margin for placement tolerance to get the required field of view.
Step 2: Match the sensor format
Magnification = sensor size ÷ field of view. Divide the long edge of the sensor by the long edge of the FOV to get the minimum magnification you need.
Step 3: Check the resolution
Object-space resolution = pixel size ÷ magnification. Confirm this value is better than one third of your measurement tolerance.
Step 4: Confirm working distance and depth of field
Pick the working distance that fits your mechanical layout, then verify the depth of field covers the height variation of the part.
Can't find what you're looking for?
We're here to help. Send us your requirements and our engineers will recommend the right solution.